Источник питаня 1500 ВТ TOE 8872-60

Свободно

Output TOE 8872-80
Voltage 0 — 80 V
Current 0 — 50 A
Power adjustable in range 100 — 1500W
Setting resolution
Voltage 20 mV
Current 10 mA
Leistung
< 1000 W 0.1 W
> 1000 W 1 W
Setting accuracy
Voltage 0.1 % + 40 mV
Current 0.2 % + 30 mA
Leistung 0.4 % + 1.5 W
Deviation in regulation with 100 % change in load
Voltage 1 x 10-4 + 5 mV
Current 5 x 10-4+25 mA
With change in line voltage ± 10 % 5 x 10-5
Regulation time with change in load from 20 % to 100 % Irated Tolerance: 0.2 % Urated 400 μs
Setting time of output voltage with change in setpoint
0 V auf Urated no-load/full load 10 ms/15 ms
Urated auf 1 V no-load/full load 300 ms/30 ms
Residual ripple (rms) 10 Hz to 10 MHz
Voltage 15 mV
Current 40 mA
Measuring accuracy
Voltage 0.1 % + 60 mV
Current 0.2 % + 60 mA
Power 0.4 % + 1.5 W
Temperature coefficient
Voltage 10-4/K
Current 10-4/K
Analog interface Control voltage (reference potential is the negative pole of the output)
0 — 10 V for 0 — 80 V
0 — 10 V for 0 — 50 A
Floating analog interface Control voltage
0 — 10 V for 0 — 80 V
0 — 10 V for 0 — 50 A
Insulation: 1 kV DC
Accuracy
Voltage 0.2 %+100 mV
Current 0.3 % +50 mA